Skip to main content

Table 2 A comparison of hemodynamic changes after laryngoscopy between the two groups

From: Comparing the effects of magnesium sulfate and lidocaine spray on hemodynamic changes caused by laryngoscopy and tracheal intubation: a randomized clinical trial

Variable

Minute 1

Minute 3

Minute 5

Minute 7

Minute 10

Systolic pressure

Lidocaine

131.1 ± 20.7

121.5 ± 16.8

116.1 ± 16.7

115.8 ± 22.8

120.2 ± 21.5

Magnesium

126.8 ± 24.0

112.1 ± 22.0

101.9 ± 18.3

104.1 ± 25.0

112.4 ± 22.6

P(t-test)

0.346

0.018

0.001

0.015

0.080

Diastolic pressure

Lidocaine

77.7 ± 17.4

75.6 ± 17.8

66.4 ± 17.0

64.8 ± 15.4

68.6 ± 19.5

Magnesium

74.2 ± 18.2

68.4 ± 21.4

67.9 ± 18.0

66.9 ± 21.0

67.0 ± 26.0

P(t-test)

0.336

0.067

0.664

0.559

0.934

Heart rate

Lidocaine

91.2 ± 21.4

89.8 ± 21.2

88.7 ± 19.9

87.5 ± 17.8

85.6 ± 16.2

Magnesium

91.9 ± 23.3

86.7 ± 18.0

86.7 ± 17.9

90.0 ± 16.5

85.8 ± 21.4

P(t-test)

0.869

0.427

0.598

0.464

0.958

Blood oxygen saturation level

Lidocaine

96.4 ± 5.1

97.1 ± 4.1

96.1 ± 5.1

96.7 ± 3.8

94.4 ± 12.9

Magnesium

97.6 ± 2.0

97.6 ± 1.9

97.1 ± 2.2

97.2 ± 2.3

96.6 ± 2.7

P(t-test)

0.121

0.367

0.226

0.429

0.239